JetAir Technologies pre-programs and runs each system before it is shipped from our factory warehouses. If your system is not running smoothly, we reccomend a handful of
trouble-shooting oberservations that have helped customers in the past.
| Problem Solution |
Support |
| Non-Start |
Check wiring.
Confirm voltages and phases. |
| Low Flow, Pressure or Vacuum |
Impeller is rotating backwards.
Dirty Filter.
Collapsed Flex Hose or Piping.
Damaged Impeller.
Closed Butterfly Valve.
Undersized Piping/Hose volume.
Air Leakage.
Loose V-Clamp.
Obstructed air inlet.
Drive programming change. |
| Electrical Overloading |
Exceeding designed blower flow.
Blower rpm too high.
Motor damage.
Drive damage.
Electrical supply problems.
Blower not connected to piping. |
| Irregular Noise |
Blockage in piping.
Leakage in piping.
Cracked hoses.
Loose bolts on mounts.
Vibrations from other machines.
Blocked Intake or Exhaust |
If you are still having problems, contact JetAir or your Distributor immediately.